CIENA-CES-PM :: cienaCesPmExtendedTxRxCurr24HBinTxExCollPkts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmExtendedTxRxCurr24HBinTxExCollPkts

cienaCesPmExtendedTxRxCurr24HBinTxExCollPkts

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmExtendedTxRxCurr24HBinTxExCollPkts

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.1.3.1.33

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of excessive collision packets transmitted on this PM instance.

What is cienaCesPmExtendedTxRxCurr24HBinTxExCollPkts?

This counts frames on this interface that had to be abandoned outright because they collided sixteen times in a row without ever getting a clean transmission, which is the point at which Ethernet's CSMA/CD retry limit gives up on the frame. Because today's still-accumulating 24-hour bin is being read from what should be a switched, full-duplex Carrier Ethernet port, hitting that 16-retry ceiling is not ordinary contention -- it almost always means this specific interface has fallen back into a duplex mismatch or is sitting behind a legacy half-duplex hub. For example, this counter reading 0 for a healthy uplink but jumping to 340 during this in-progress 24-hour bin would be the signal to check this exact port's negotiated duplex setting before blaming the application above it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.3.1.33
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxCurr24HBinTxExCollPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.3.1.33.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxCurr24HBinTxExCollPkts.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmExtendedTxRxCurr24HBinTxExCollPkts OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1cienaCesPmExtendedTxRxStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.3cienaCesPmExtendedTxRxCurr24HBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.3.1cienaCesPmExtendedTxRxCurr24HBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.3.1.33cienaCesPmExtendedTxRxCurr24HBinTxExCollPktsCIENA-CES-PM