CIENA-CES-PM :: cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts

cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.24

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of CRC error packets transmitted on the interface.

What is cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts?

This field reports the number of CRC error packets transmitted on the interface, exposed here as cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts. On this Ciena CES port's PM data, normally a device computes a correct FCS before it transmits, so a nonzero count here — the device itself sending out a frame with a bad checksum — points at an internal hardware fault on this port's transmit path rather than anything happening out on the wire; and this 'all-time' counter for the extended Tx/Rx PM group has no fixed rollover schedule of its own — it just keeps accumulating from whenever the PM instance was last cleared, so a single reading only tells you the running total, not a rate. For example, a healthy port would sit at 0 for CRC-error frames transmitted in this bin; even 32 is enough to warrant a look, since this class of counter isn't supposed to move under normal operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.24
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.24.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPkts OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1cienaCesPmExtendedTxRxStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.5cienaCesPmExtendedTxRxAllTimeBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1cienaCesPmExtendedTxRxAllTimeBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.24cienaCesPmExtendedTxRxAllTimeBinTxCrcErrorPktsCIENA-CES-PM