cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.3

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of packets received with CRC errors by this PM instance.

What is cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts?

This field reports the number of packets received with CRC errors by this PM instance, exposed here as cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts. On this Ciena CES port's PM data, a CRC/FCS mismatch means the frame's checksum didn't match its contents by the time it reached this port's MAC, which is a physical-layer signal-integrity symptom — bad cable, dirty connector, marginal optic, or a failing NIC on the far end — not a software or config issue; and this 'all-time' counter for the extended Tx/Rx PM group has no fixed rollover schedule of its own — it just keeps accumulating from whenever the PM instance was last cleared, so a single reading only tells you the running total, not a rate. For example, a healthy port would sit at 0 for CRC-error frames in this bin; even 26 is enough to warrant a look, since this class of counter isn't supposed to move under normal operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.3
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.3.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPkts OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1cienaCesPmExtendedTxRxStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.5cienaCesPmExtendedTxRxAllTimeBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1cienaCesPmExtendedTxRxAllTimeBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.5.1.3cienaCesPmExtendedTxRxAllTimeBinRxCrcErrorPktsCIENA-CES-PM