CIENA-CES-PM :: cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec

cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.12.6.1.10

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of forward tunnel bytes received per second on this PM instance.

What is cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec?

This Counter64 field reports the bytes received per second on the forward direction of this bidirectional CES tunnel, as computed for this PM instance. Because this TotalStats row has neither a clear-time nor a Duration/State field — it is the true lifetime, never-reset total for this PM instance since it was provisioned, and this specific field is an instantaneous computed rate of accepted ingress traffic rather than a running total, so it reacts immediately to a burst instead of waiting for a bin to close, it is the field to check when you need to see the forward-direction ingress throughput of the tunnel right now rather than a cumulative volume. For example, this counter might read 7,712 bytes/sec during the lifetime of this PM instance — a sudden jump to several times that on the forward side, with no matching rise on the other direction, would point to a one-way traffic surge or an attack riding that leg of the tunnel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.12.6.1.10
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.12.6.1.10.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSec OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12cienaCesPmBasicTxRxBiDirStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.6cienaCesPmBasicTxRxBiDirTotalStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.6.1cienaCesPmBasicTxRxBiDirTotalStatisticsBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.6.1.10cienaCesPmBasicTxRxBiDirTotalStatsBinFwdRxBytesPerSecCIENA-CES-PM