CIENA-CES-PM :: cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec

cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.12.1.1.30

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of reverse tunnel frames transmitted per second on this PM instance.

What is cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec?

This Counter64 field reports the frames transmitted per second on the reverse direction of this bidirectional CES tunnel, as computed for this PM instance. Because this row is a closed, already-completed measurement interval kept in the CES-PM history table — a fixed, immutable snapshot of one specific past window, and this specific field is an instantaneous computed rate of transmitted egress traffic rather than a running total, so a spike here shows up the moment it happens rather than only after the interval ends, it is the field to check when you need to see the reverse-direction egress throughput of the tunnel right now rather than a cumulative volume. For example, this counter might read 3,235 frames/sec during the most recently completed 15-minute bin — if that number spikes on the reverse side while the opposite direction stays flat, it flags an asymmetric load or fault specific to that leg of the tunnel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.12.1.1.30
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.12.1.1.30.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSec OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12cienaCesPmBasicTxRxBiDirStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.1cienaCesPmBasicTxRxBiDirHistoryBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.1.1cienaCesPmBasicTxRxBiDirHistoryBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.1.1.30cienaCesPmBasicTxRxBiDirHistoryBinRevTxFramesPerSecCIENA-CES-PM