CIENA-CES-PM :: cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec

cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.12.4.1.16

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of forward tunnel bytes transmitted per second on this PM instance.

What is cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec?

This Counter64 field reports the bytes transmitted per second on the forward direction of this bidirectional CES tunnel, as computed for this PM instance. Because this row is a completed prior day's 24-hour bin kept in the daily-history table, letting you compare one calendar day against another after the fact, and this specific field is an instantaneous computed rate of transmitted egress traffic rather than a running total, so a spike here shows up the moment it happens rather than only after the interval ends, it is the field to check when you need to see the forward-direction egress throughput of the tunnel right now rather than a cumulative volume. For example, this counter might read 5,899 bytes/sec during yesterday's completed 24-hour bin — a sudden jump to several times that on the forward side, with no matching rise on the other direction, would point to a one-way traffic surge or an attack riding that leg of the tunnel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.12.4.1.16
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.12.4.1.16.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSec OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12cienaCesPmBasicTxRxBiDirStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.4cienaCesPmBasicTxRxBiDirHist24HBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.4.1cienaCesPmBasicTxRxBiDirHist24HBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.12.4.1.16cienaCesPmBasicTxRxBiDirHist24HBinBasicFwdTxBytesPerSecCIENA-CES-PM