CIENA-CES-PM :: cienaCesPmBasicPtpHistoryBinFieldsUnsupported

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicPtpHistoryBinFieldsUnsupported

cienaCesPmBasicPtpHistoryBinFieldsUnsupported

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicPtpHistoryBinFieldsUnsupported

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.13.1.1.7

Node type: OBJECT-TYPE

Type: PmProfileFieldMapBasicPtp

Access: read-only

Description: Mapping of the fields within this profile which have been declared unsupported. The value of any fields indicated by this object within the same table row should be disregarded.

What is cienaCesPmBasicPtpHistoryBinFieldsUnsupported?

This PmProfileFieldMapBasicPtp field is a bitmap indicating which specific fields within this Basic PTP history profile the device has declared unsupported for this particular timing session or hardware. Because this row is a closed, completed interval from the PTP performance-monitoring history table for this timing session, any bit set here means the corresponding counter or measurement elsewhere in this same row was never actually collected by this hardware/firmware combination, so it should be ignored rather than read as a real zero or low value. For example, if the bit for the optical-power field is set here, an OprOch value of 0 in the same row does not mean zero optical power was measured — it means the device could not measure it at all on this port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.13.1.1.7
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicPtpHistoryBinFieldsUnsupported

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.13.1.1.7.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicPtpHistoryBinFieldsUnsupported.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicPtpHistoryBinFieldsUnsupported OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.13cienaCesPmBasicPtpStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.13.1cienaCesPmBasicPtpHistoryBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.13.1.1cienaCesPmBasicPtpHistoryBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.13.1.1.7cienaCesPmBasicPtpHistoryBinFieldsUnsupportedCIENA-CES-PM