CIENA-CES-PM :: cienaCesPmBasicOtuStatsBinSesOtu

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicOtuStatsBinSesOtu

cienaCesPmBasicOtuStatsBinSesOtu

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOtuStatsBinSesOtu

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.5

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Severely Errored Seconds, Optical Transport Unit.

What is cienaCesPmBasicOtuStatsBinSesOtu?

This counts Severely Errored Seconds at the OTU (Optical Transport Unit -- the outer G.709 section that wraps the signal and carries FEC): seconds where the error rate on the OTU frame crossed a much higher threshold than plain ES, per the MIB's description. SES on this OTU section is the metric that actually drives SLA penalties, because a handful of SES in a 15-minute bin signals the link briefly dropped to near-unusable quality rather than just having a stray parity error; this particular bin is a live counter that keeps accumulating until it is explicitly cleared rather than rolling over on a fixed 15-minute or 24-hour schedule, so a large value mostly reflects how long it has been since the last clear. For instance 1 severely errored seconds in this bin would be enough for a carrier-grade circuit to flag the interval for review, whereas a run of zeros across consecutive bins is the normal expectation for this kind of port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.5
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOtuStatsBinSesOtu

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.5.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOtuStatsBinSesOtu.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOtuStatsBinSesOtu OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.14cienaCesPmBasicOtuStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.14.5cienaCesPmBasicOtuStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1cienaCesPmBasicOtuStatisticsBinEntryCIENA-CES-PM