cienaCesPmBasicOtuStatsBinPrfBerMaxOtu

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPrfBerMaxOtu

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.10

Node type: OBJECT-TYPE

Type: PmCounter64Atto

Access: read-only

Description: Pre-FEC Bit Max Error Rate, Optical Transport Unit.

What is cienaCesPmBasicOtuStatsBinPrfBerMaxOtu?

This is the peak (maximum) Pre-FEC Bit Error Rate observed during the bin at the OTU layer, encoded as a PmCounter64Atto atto-scaled integer, per the MIB's description. Because the average pre-FEC BER can hide a brief spike, this max value on this specific bin is what catches a short burst of degradation -- e.g. a micro-bend flexing in the wind or a transient laser wobble -- that an averaged reading for the same interval would smooth away; this particular bin is a live counter that keeps accumulating until it is explicitly cleared rather than rolling over on a fixed 15-minute or 24-hour schedule, so a large value mostly reflects how long it has been since the last clear. If the average pre-FEC BER for this bin looks healthy but this max field corresponds to something like 1e-9, that gap alone tells an admin the link had at least one rough moment worth investigating within that window.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.10
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPrfBerMaxOtu

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.10.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPrfBerMaxOtu.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPrfBerMaxOtu OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.14cienaCesPmBasicOtuStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.14.5cienaCesPmBasicOtuStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1cienaCesPmBasicOtuStatisticsBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.10cienaCesPmBasicOtuStatsBinPrfBerMaxOtuCIENA-CES-PM