All MIBs › CIENA-CES-PM › cienaCesPmBasicOtuStatsBinPfBerEOtu
cienaCesPmBasicOtuStatsBinPfBerEOtu
Module: CIENA-CES-PM
OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPfBerEOtu
OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.11
Node type: OBJECT-TYPE
Type: PmCounter64Atto
Access: read-only
Description: Post-FEC Bit Error Rate Estimate, Optical Transport Unit.
What is cienaCesPmBasicOtuStatsBinPfBerEOtu?
This is the Post-FEC Bit Error Rate Estimate at the OTU layer, encoded as a PmCounter64Atto atto-scaled integer -- a model-derived estimate of the residual error rate remaining after FEC correction is applied, per the MIB's description. Post-FEC BER on this section is essentially the 'did FEC actually clean it up' number -- it should sit vanishingly close to zero on a healthy link, and any measurable uptick here (even while pre-FEC BER looks only moderately worse) means FEC's correction headroom on this specific port is starting to run out; this particular bin is a live counter that keeps accumulating until it is explicitly cleared rather than rolling over on a fixed 15-minute or 24-hour schedule, so a large value mostly reflects how long it has been since the last clear. A healthy reading for this bin would correspond to well under 1e-15, essentially error-free after correction, whereas a jump toward 1e-9 would be treated as a leading indicator that this OTU section is approaching its FEC correction limit.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.11 snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPfBerEOtu
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.11.1 snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPfBerEOtu.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOtuStatsBinPfBerEOtu OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.3 | cienaCesStatistics | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.3.1 | cienaCesPmMib | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2 | cienaCesPmMIBObjects | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3 | cienaCesPmStatistics | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.14 | cienaCesPmBasicOtuStats | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.14.5 | cienaCesPmBasicOtuStatisticsBinTable | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1 | cienaCesPmBasicOtuStatisticsBinEntry | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.14.5.1.11 | cienaCesPmBasicOtuStatsBinPfBerEOtu | CIENA-CES-PM |