CIENA-CES-PM :: cienaCesPmBasicOduTotalStatsBinEsOdu

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicOduTotalStatsBinEsOdu

cienaCesPmBasicOduTotalStatsBinEsOdu

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOduTotalStatsBinEsOdu

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.15.6.1.3

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Errored Seconds, Optical Data Unit.

What is cienaCesPmBasicOduTotalStatsBinEsOdu?

This counts Errored Seconds at the ODU (Optical Data Unit -- the inner G.709 container that carries the actual client payload): the number of one-second intervals in the bin during which an error was detected on the client payload container carried inside this OTN wrapper. ES at the ODU layer tells an admin how many seconds of the bin saw trouble specifically in the mapped client signal (e.g. the 10GbE or SONET payload riding inside this ODU), which is what actually matters to the service running over this circuit even if the underlying OTU section looks clean; as a 'total' bin it never rolls over on its own the way the 15-minute and 24-hour bins do -- it only resets on an explicit clear or a card reset, so a high count here just reflects long uptime, not necessarily an active problem. A typical reading for this bin might be 5 errored seconds, which an admin would compare against the bin's total duration to get a rough availability percentage for this specific interval.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.6.1.3
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduTotalStatsBinEsOdu

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.6.1.3.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduTotalStatsBinEsOdu.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOduTotalStatsBinEsOdu OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15cienaCesPmBasicOduStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.6cienaCesPmBasicOduTotalStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.6.1cienaCesPmBasicOduTotalStatisticsBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.6.1.3cienaCesPmBasicOduTotalStatsBinEsOduCIENA-CES-PM