CIENA-CES-PM :: cienaCesPmBasicOduStatsBinFcOdu

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicOduStatsBinFcOdu

cienaCesPmBasicOduStatsBinFcOdu

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOduStatsBinFcOdu

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.15.5.1.7

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Failure Count, Optical Data Unit.

What is cienaCesPmBasicOduStatsBinFcOdu?

This counts Failure Count at the ODU layer: the number of distinct failure events (such as AIS or loss-of-frame declarations) recorded against this payload container during the bin, per the MIB's description. FC matters on this specific ODU because it tells an admin how many separate incidents occurred, not just how many seconds were affected -- one long outage and ten short flaps can produce the same UAS total but a very different FC, and the FC number is what points toward a flapping/intermittent fault rather than a single sustained one; this particular bin is a live counter that keeps accumulating until it is explicitly cleared rather than rolling over on a fixed 15-minute or 24-hour schedule, so a large value mostly reflects how long it has been since the last clear. A count of 4 failures in this bin, especially if UAS for the same bin is comparatively low, would suggest a series of brief flaps on this ODU rather than one continuous outage -- worth checking against the port's alarm log for repeated AIS declarations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.5.1.7
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduStatsBinFcOdu

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.5.1.7.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduStatsBinFcOdu.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOduStatsBinFcOdu OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15cienaCesPmBasicOduStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.5cienaCesPmBasicOduStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.5.1cienaCesPmBasicOduStatisticsBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.5.1.7cienaCesPmBasicOduStatsBinFcOduCIENA-CES-PM