CIENA-CES-PM :: cienaCesPmBasicOduHistoryBinState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicOduHistoryBinState

cienaCesPmBasicOduHistoryBinState

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOduHistoryBinState

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.6

Node type: OBJECT-TYPE

Type: PmBinState

Access: read-only

Description: State of the bin.

What is cienaCesPmBasicOduHistoryBinState?

This is the State of this ODU-layer bin, an enumerated value (PmBinState) whose exact label set isn't given in this excerpt, but per the MIB's description it reflects the bin's own status. Before trusting the CvOdu/EsOdu/SesOdu/UasOdu/FcOdu values sitting in this same row at face value, an admin would check this state field first, since it's what would flag whether the ODU bin's own measurement window was complete and valid rather than cut short by a reset or day-change; because this specific bin belongs to the completed-interval history table, its value is frozen the moment the interval closes, so re-polling it later will return the same number -- useful for pinpointing exactly which past 15 minutes a problem occurred in. If this field for a given row came back indicating an incomplete or invalid state, an admin would discard the FcOdu/UasOdu values sitting next to it in that row rather than read a zero failure count as good news.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.6
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduHistoryBinState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.6.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduHistoryBinState.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOduHistoryBinState OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15cienaCesPmBasicOduStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.1cienaCesPmBasicOduHistoryBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1cienaCesPmBasicOduHistoryBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.6cienaCesPmBasicOduHistoryBinStateCIENA-CES-PM