CIENA-CES-PM :: cienaCesPmBasicOduHistoryBinFcOdu

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicOduHistoryBinFcOdu

cienaCesPmBasicOduHistoryBinFcOdu

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOduHistoryBinFcOdu

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.13

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Failure Count, Optical Data Unit.

What is cienaCesPmBasicOduHistoryBinFcOdu?

This counts Failure Count at the ODU layer: the number of distinct failure events (such as AIS or loss-of-frame declarations) recorded against this payload container during the bin, per the MIB's description. FC matters on this specific ODU because it tells an admin how many separate incidents occurred, not just how many seconds were affected -- one long outage and ten short flaps can produce the same UAS total but a very different FC, and the FC number is what points toward a flapping/intermittent fault rather than a single sustained one; because this specific bin belongs to the completed-interval history table, its value is frozen the moment the interval closes, so re-polling it later will return the same number -- useful for pinpointing exactly which past 15 minutes a problem occurred in. A count of 1 failures in this bin, especially if UAS for the same bin is comparatively low, would suggest a series of brief flaps on this ODU rather than one continuous outage -- worth checking against the port's alarm log for repeated AIS declarations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.13
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduHistoryBinFcOdu

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.13.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduHistoryBinFcOdu.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOduHistoryBinFcOdu OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15cienaCesPmBasicOduStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.1cienaCesPmBasicOduHistoryBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1cienaCesPmBasicOduHistoryBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.1.1.13cienaCesPmBasicOduHistoryBinFcOduCIENA-CES-PM