All MIBs › CIENA-CES-PM › cienaCesPmBasicOduCurr24HBinFieldsInvalid
cienaCesPmBasicOduCurr24HBinFieldsInvalid
Module: CIENA-CES-PM
OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFieldsInvalid
OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.6
Node type: OBJECT-TYPE
Type: PmProfileFieldMapBasicOdu
Access: read-only
Description: Mapping of the fields within this profile which have been declared invalid. The value of any fields indicated by this object within the same table row should be treated as untrustworthy.
What is cienaCesPmBasicOduCurr24HBinFieldsInvalid?
This is a bitmap (PmProfileFieldMapBasicOdu) that marks which counters within this same profile/row have been declared invalid, per the MIB's description, meaning any field flagged here should be treated as untrustworthy rather than simply absent. Unlike the 'unsupported' bitmap, this one flags fields that the device did attempt to measure but doesn't trust -- e.g. because the bin was affected by a reset or clock event mid-measurement -- so an admin seeing an alarming CV or SES spike in this same row should check this bitmap before escalating, since the spike might be a measurement artifact rather than a real event; because this bin spans the whole current day and is still open, short error bursts get averaged into a slower-moving daily total -- useful for spotting a low-grade, chronic problem that the 15-minute bins would report as merely noisy. If the bit for EsOdu is set here for a given row, an admin would flag any errored-second value reported in that same row as unreliable for that interval rather than feed it into a trend chart.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.6 snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFieldsInvalid
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.6.1 snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFieldsInvalid.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFieldsInvalid OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.3 | cienaCesStatistics | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.3.1 | cienaCesPmMib | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2 | cienaCesPmMIBObjects | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3 | cienaCesPmStatistics | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.15 | cienaCesPmBasicOduStats | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.15.3 | cienaCesPmBasicOduCurr24HBinTable | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1 | cienaCesPmBasicOduCurr24HBinEntry | CIENA-CES-PM |
| 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.6 | cienaCesPmBasicOduCurr24HBinFieldsInvalid | CIENA-CES-PM |