CIENA-CES-PM :: cienaCesPmBasicOduCurr24HBinFcOdu

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmBasicOduCurr24HBinFcOdu

cienaCesPmBasicOduCurr24HBinFcOdu

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFcOdu

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.11

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Failure Count, Optical Data Unit.

What is cienaCesPmBasicOduCurr24HBinFcOdu?

This counts Failure Count at the ODU layer: the number of distinct failure events (such as AIS or loss-of-frame declarations) recorded against this payload container during the bin, per the MIB's description. FC matters on this specific ODU because it tells an admin how many separate incidents occurred, not just how many seconds were affected -- one long outage and ten short flaps can produce the same UAS total but a very different FC, and the FC number is what points toward a flapping/intermittent fault rather than a single sustained one; because this bin spans the whole current day and is still open, short error bursts get averaged into a slower-moving daily total -- useful for spotting a low-grade, chronic problem that the 15-minute bins would report as merely noisy. A count of 4 failures in this bin, especially if UAS for the same bin is comparatively low, would suggest a series of brief flaps on this ODU rather than one continuous outage -- worth checking against the port's alarm log for repeated AIS declarations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.11
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFcOdu

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.11.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFcOdu.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmBasicOduCurr24HBinFcOdu OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15cienaCesPmBasicOduStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.3cienaCesPmBasicOduCurr24HBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1cienaCesPmBasicOduCurr24HBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.15.3.1.11cienaCesPmBasicOduCurr24HBinFcOduCIENA-CES-PM