cienaCesPmAdjustmentTcaConfigStatus

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmAdjustmentTcaConfigStatus

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.3.3.1.1.7

Node type: OBJECT-TYPE

Type: PmTcaConfigStatus

Access: read-only

Description: This object indicates whether the Adjustment TCA configuration attributes are configured in a way for periodic Adjustment TCA events to occur on behalf of the PM Instance. This status refers to the Adjustment TCA functionality comprising of the following necessary configuration attributes: 1. cienaCesPmIntervalProfileAdjustmentInterval 2. cienaCesPmIntervalProfileAdjustmentThreshold or cienaCesPmIntervalProfileAdjustmentThresholdPercentage

noProfile indicates there is no interval profile configured for the PM Instance.

notConfigured indicates the PM instance is configured with a particular interval profile, however none of the necessary configuration attributes for the Adjustment TCA feature are configured.

partiallyConfigured indicates the PM instance is configured with a particular interval profile and that some, but not all, of the necessary configuration attributes for the Adjustment TCA feature are configured.

configured indicates the PM instance is configured with a particular interval profile and that all of the necessary configuration attributes for the Adjustment TCA feature are configured.

What is cienaCesPmAdjustmentTcaConfigStatus?

This PmTcaConfigStatus reports whether the specific set of attributes the Adjustment TCA feature needs -- starting with cienaCesPmIntervalProfileAdjustmentInterval and cienaCesPmIntervalProfileAdjustmentThreshold, per its (truncated) DESCRIPTION list -- are actually all configured well enough for periodic Adjustment TCA events to occur on this instance. Because Adjustment TCA depends on several separate objects being set consistently across the interval profile, this status object exists so an operator or NMS can check in one read whether the feature is actually live on a given instance, instead of manually verifying each contributing object individually and reasoning out whether the combination is complete. For example, a profile with a configured AdjustmentInterval but where AdjustmentThreshold was left unset (value 0) would show this status as incomplete, immediately telling an operator why no Adjustment TCAs have ever fired despite the interval being configured.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.3.3.1.1.7
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmAdjustmentTcaConfigStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.3.3.1.1.7.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmAdjustmentTcaConfigStatus.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmAdjustmentTcaConfigStatus OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.3cienaCesPmThresholdCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.3.3cienaCesPmInstanceAdjustmentTcaCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.3.3.1cienaCesPmInstanceAdjustmentTcaTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.3.3.1.1cienaCesPmInstanceAdjustmentTcaEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.3.3.1.1.7cienaCesPmAdjustmentTcaConfigStatusCIENA-CES-PM