CIENA-CES-NOTIFICATIONS-CONTROL :: cienaCesChassisAllFanTempTrapState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-NOTIFICATIONS-CONTROLcienaCesChassisAllFanTempTrapState

cienaCesChassisAllFanTempTrapState

Module: CIENA-CES-NOTIFICATIONS-CONTROL

OID (symbolic): CIENA-CES-NOTIFICATIONS-CONTROL::cienaCesChassisAllFanTempTrapState

OID (numeric): 1.3.6.1.4.1.1271.2.2.1.1.1.17

Node type: OBJECT-TYPE

Type: CienaGlobalState

Access: read-write

Description: This object indicates whether the device sends out chassis fan temperature related traps.

What is cienaCesChassisAllFanTempTrapState?

This read-write switch controls whether the device generates traps specifically tied to fan-related temperature thresholds, likely alarms triggered when cooling performance, as measured by temperature near the fan system, crosses a defined limit, distinct from a simple fan-failure trap. This gives an admin visibility into thermal stress building up in the chassis even before an individual fan outright fails, serving as an intermediate warning stage between normal operation and a hard fan failure. If chassis temperatures are trending upward across multiple monitoring cycles, having this trap enabled ensures the crossing of a defined threshold is actively reported rather than only discovered through manual periodic checks.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.2.1.1.1.17
snmpwalk -v2c -c public <target> CIENA-CES-NOTIFICATIONS-CONTROL::cienaCesChassisAllFanTempTrapState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.2.1.1.1.17.1
snmpget -v2c -c public <target> CIENA-CES-NOTIFICATIONS-CONTROL::cienaCesChassisAllFanTempTrapState.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1271.2.2.1.1.1.17.1 s <value>

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-NOTIFICATIONS-CONTROL::cienaCesChassisAllFanTempTrapState OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.2cienaCesNotificationsCIENA-SMI
1.3.6.1.4.1.1271.2.2.1cienaCesNotificationsControlModuleCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.2.1.1cienaCesNotificationsControlMIBCIENA-CES-NOTIFICATIONS-CONTROL
1.3.6.1.4.1.1271.2.2.1.1.1cienaCesNotificationsControlCIENA-CES-NOTIFICATIONS-CONTROL
1.3.6.1.4.1.1271.2.2.1.1.1.17cienaCesChassisAllFanTempTrapStateCIENA-CES-NOTIFICATIONS-CONTROL