All MIBs › CHIPCOMMIB › oc61nnMTPLPortBuddySlot
oc61nnMTPLPortBuddySlot
Module: CHIPCOMMIB
OID (symbolic): CHIPCOMMIB::oc61nnMTPLPortBuddySlot
OID (numeric): 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The slot index of the redundant port's buddy. To set
a port to be redundant, the buddy's slot and port must
be set to valid values.
The buddy is automatically set to be redundant to this port.
If the port is configured for remote diagnostics, then
this contains the slot index of the backup buddy port.
To configure a port for remote diagnostics, the buddy's
slot and port must be set to valid values.
What is oc61nnMTPLPortBuddySlot?
A read-write value specifying the slot index of the redundant (buddy) port paired with this port, or, for remote diagnostics, the slot of the associated diagnostic port; the buddy port is automatically marked redundant when set.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.4 snmpwalk -v2c -c public <target> CHIPCOMMIB::oc61nnMTPLPortBuddySlot
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.4.1 snmpget -v2c -c public <target> CHIPCOMMIB::oc61nnMTPLPortBuddySlot.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.4.1 i <value>
Start monitoring Chipcom (3Com) Ethernet/Token Ring switching hub or LAN concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CHIPCOMMIB::oc61nnMTPLPortBuddySlot OID value, configure state conditions and alerts, and monitor any Chipcom (3Com) Ethernet/Token Ring switching hub or LAN concentrator (legacy) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.49 | chipcom | CHIPAGENT-MIB |
| 1.3.6.1.4.1.49.2 | chipmib02 | CHIPAGENT-MIB |
| 1.3.6.1.4.1.49.2.3 | chipProducts | CHIPAGENT-MIB |
| 1.3.6.1.4.1.49.2.3.1 | online | CHIPAGENT-MIB |
| 1.3.6.1.4.1.49.2.3.1.4 | olModules | CHIPAGENT-MIB |
| 1.3.6.1.4.1.49.2.3.1.4.4 | olSpecMods | CHIPAGENT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.49.2.3.1.4.4.47 | oc61nnMTPL | CHIPCOMMIB |
| 1.3.6.1.4.1.49.2.3.1.4.4.47.2 | oc61nnMTPLPortTable | CHIPCOMMIB |
| 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1 | oc61nnMTPLPortEntry | CHIPCOMMIB |
| 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.4 | oc61nnMTPLPortBuddySlot | CHIPCOMMIB |