Description: ODU Faults

Value Description of status parameter

0 No ODU faults 1 BUC PLL 3 BUC current 5 BUC voltage 7 LNB current 9 LNB voltage 11 BUC temperature 13 BUC checksum

What is cdm570LODUAlarms?

This reports the current outdoor-unit fault condition as one of a fixed set of codes covering BUC PLL, current, voltage, temperature, and checksum faults, plus the equivalent current and voltage faults for the LNB. Because a single object carries all these distinct fault types, an NMS polling this can immediately narrow down which specific ODU subsystem is failing without polling each individual BUC or LNB telemetry object separately. A value of bucPLL(1) points straight at the BUC's phase-locked loop failing to lock, distinct from a value of lnbVoltage(9) which would instead point to the LNB's power feed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.3.1.4
snmpwalk -v2c -c public <target> CDM-570L::cdm570LODUAlarms

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.3.1.4.1
snmpget -v2c -c public <target> CDM-570L::cdm570LODUAlarms.1

Start monitoring Comtech EF Data satellite modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDM-570L::cdm570LODUAlarms OID value, configure state conditions and alerts, and monitor any Comtech EF Data satellite modems from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6247comtechEFDataComtechEFData
1.3.6.1.4.1.6247.24cdm570CDM-570
1.3.6.1.4.1.6247.24.1cdm570ObjectsCDM-570
1.3.6.1.4.1.6247.24.1.3cdm570MonitorCDM-570
1.3.6.1.4.1.6247.24.1.3.1cdm570AlarmsCDM-570
Numeric OIDNameModule
1.3.6.1.4.1.6247.24.1.3.1.4cdm570LODUAlarmsCDM-570L