CDM-570L :: cdm570LBUCTemperature

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CDM-570L › cdm570LBUCTemperature

cdm570LBUCTemperature

Module: CDM-570L

OID (symbolic): CDM-570L::cdm570LBUCTemperature

OID (numeric): 1.3.6.1.4.1.6247.24.1.3.6.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates the BUC temperature in degrees Celsius. If not available, response is -99.

Note: This query is only valid when FSK and BUC power are turned On.

What is cdm570LBUCTemperature?

This reports the BUC's internal temperature in degrees Celsius, returning -99 specifically when the reading is not available. Since the description notes this query is only valid when FSK comms and BUC power are both on, a persistent -99 reading does not necessarily mean overheating; it could just mean cdm570LBUCComms or cdm570LBUCDCPower is currently off, which an admin has to rule out before treating -99 as a sensor fault. A climbing reading from 35 up toward 70-plus degrees C on a BUC mounted in direct summer sun would warrant checking for a ventilation or fan issue before it triggers a thermal shutdown.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.3.6.1.3
snmpwalk -v2c -c public <target> CDM-570L::cdm570LBUCTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.3.6.1.3.1
snmpget -v2c -c public <target> CDM-570L::cdm570LBUCTemperature.1

Start monitoring Comtech EF Data satellite modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDM-570L::cdm570LBUCTemperature OID value, configure state conditions and alerts, and monitor any Comtech EF Data satellite modems from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6247comtechEFDataComtechEFData
1.3.6.1.4.1.6247.24cdm570CDM-570
1.3.6.1.4.1.6247.24.1cdm570ObjectsCDM-570
1.3.6.1.4.1.6247.24.1.3cdm570MonitorCDM-570
1.3.6.1.4.1.6247.24.1.3.6cdm570ODUParamsCDM-570
Numeric OIDNameModule
1.3.6.1.4.1.6247.24.1.3.6.1cdm570LBUCParamsCDM-570L
1.3.6.1.4.1.6247.24.1.3.6.1.3cdm570LBUCTemperatureCDM-570L