CDM-570L :: cdm570LBUCLOMix

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CDM-570L › cdm570LBUCLOMix

cdm570LBUCLOMix

Module: CDM-570L

OID (symbolic): CDM-570L::cdm570LBUCLOMix

OID (numeric): 1.3.6.1.4.1.6247.24.1.2.8.1.5.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: BUC LO frequency mix, where: 0 = Low-side mix 1 = High-side mix

What is cdm570LBUCLOMix?

This selects whether the BUC's LO frequency is added to or subtracted from the modem's Tx frequency to derive the final uplink RF frequency. Because Terminal Frequency = BUC_LO plus or minus Tx_Frequency depending on this setting, choosing the wrong mix produces a transmit frequency off by twice the Tx IF offset, potentially transmitting into an entirely different, occupied satellite channel. Selecting highSideMix(1) with a 13050 MHz LO and 1000 MHz Tx frequency yields 14050 MHz uplink, whereas lowSideMix(0) with the same numbers would instead target 12050 MHz.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.8.1.5.2
snmpwalk -v2c -c public <target> CDM-570L::cdm570LBUCLOMix

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.8.1.5.2.1
snmpget -v2c -c public <target> CDM-570L::cdm570LBUCLOMix.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.24.1.2.8.1.5.2.1 i <value>

Start monitoring Comtech EF Data satellite modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDM-570L::cdm570LBUCLOMix OID value, configure state conditions and alerts, and monitor any Comtech EF Data satellite modems from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6247comtechEFDataComtechEFData
1.3.6.1.4.1.6247.24cdm570CDM-570
1.3.6.1.4.1.6247.24.1cdm570ObjectsCDM-570
1.3.6.1.4.1.6247.24.1.2cdm570ConfigCDM-570
1.3.6.1.4.1.6247.24.1.2.8cdm570ODUCDM-570
Numeric OIDNameModule
1.3.6.1.4.1.6247.24.1.2.8.1cdm570LBUCCDM-570L
1.3.6.1.4.1.6247.24.1.2.8.1.5cdm570LBUCLOCDM-570L
1.3.6.1.4.1.6247.24.1.2.8.1.5.2cdm570LBUCLOMixCDM-570L