All MIBs › CDM-570L › cdm570LBUCHighCurrentLimit
cdm570LBUCHighCurrentLimit
Module: CDM-570L
OID (symbolic): CDM-570L::cdm570LBUCHighCurrentLimit
OID (numeric): 1.3.6.1.4.1.6247.24.1.2.8.1.4.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: BUC high current limit, between 500 and 4000 mA.
What is cdm570LBUCHighCurrentLimit?
This sets the upper current threshold, in mA, above which the modem raises a BUC over-current alarm. Because BUC current draw correlates with output power and can spike on a fault such as an output mismatch or internal short, this threshold is what turns a raw current reading into an actionable alarm rather than just a number to eyeball. Setting this to 2500 mA on a 150-watt BUC that nominally draws around 2000 mA gives headroom for normal variation while still catching a genuine over-current fault.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.8.1.4.1 snmpwalk -v2c -c public <target> CDM-570L::cdm570LBUCHighCurrentLimit
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.24.1.2.8.1.4.1.1 snmpget -v2c -c public <target> CDM-570L::cdm570LBUCHighCurrentLimit.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.24.1.2.8.1.4.1.1 i <value>
Start monitoring Comtech EF Data satellite modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDM-570L::cdm570LBUCHighCurrentLimit OID value, configure state conditions and alerts, and monitor any Comtech EF Data satellite modems from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6247 | comtechEFData | ComtechEFData |
| 1.3.6.1.4.1.6247.24 | cdm570 | CDM-570 |
| 1.3.6.1.4.1.6247.24.1 | cdm570Objects | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.2 | cdm570Config | CDM-570 |
| 1.3.6.1.4.1.6247.24.1.2.8 | cdm570ODU | CDM-570 |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6247.24.1.2.8.1 | cdm570LBUC | CDM-570L |
| 1.3.6.1.4.1.6247.24.1.2.8.1.4 | cdm570LBUCAlarm | CDM-570L |
| 1.3.6.1.4.1.6247.24.1.2.8.1.4.1 | cdm570LBUCHighCurrentLimit | CDM-570L |