CDATA-GPON-MIB :: gponOnuIpCfgIp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCDATA-GPON-MIBgponOnuIpCfgIp

gponOnuIpCfgIp

Module: CDATA-GPON-MIB

OID (symbolic): CDATA-GPON-MIB::gponOnuIpCfgIp

OID (numeric): 1.3.6.1.4.1.34592.1.5.1.1.2.20.2.1.6

Node type: OBJECT-TYPE

Type: IpAddress

Access: read-create

Description: Description.

What is gponOnuIpCfgIp?

This is the static IP address for the ONU's management interface when the IP mode is set to static, the address an admin would ping, telnet, or SNMP-poll directly to reach this specific unit out-of-band from any of its customer WAN connections. For example, an admin troubleshooting a unit whose customer WAN connections are all down can still often reach this management IP directly to pull diagnostics.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.34592vendorCDATA-COMMON-SMI
1.3.6.1.4.1.34592.1ipProductCDATA-COMMON-SMI
1.3.6.1.4.1.34592.1.5gponCDATA-COMMON-SMI
Numeric OIDNameModule
1.3.6.1.4.1.34592.1.5.1gponMIBCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1gponObjectsCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2gponControlObjectsCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.20gponOnuPotsPortObjectsCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.20.2gponOnuIpCfgTableCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.20.2.1gponOnuIpCfgEntryCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.20.2.1.6gponOnuIpCfgIpCDATA-GPON-MIB