CDATA-GPON-MIB :: gponOltPortDdmTemperature

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCDATA-GPON-MIBgponOltPortDdmTemperature

gponOltPortDdmTemperature

Module: CDATA-GPON-MIB

OID (symbolic): CDATA-GPON-MIB::gponOltPortDdmTemperature

OID (numeric): 1.3.6.1.4.1.34592.1.5.1.1.2.17.2.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Description.

What is gponOltPortDdmTemperature?

This read-only OCTET STRING reports the real-time operating temperature of the PON port's SFP transceiver via its Digital Diagnostic Monitoring interface. Admins watch this for gradual drift that predicts an eventual optic failure or a cooling problem in that OLT slot. For example, a technician checking gponOltPortDdmTemperature while troubleshooting intermittent PON dropouts finds the transceiver running abnormally hot, near 70 degrees Celsius, pointing to a cooling problem in that shelf slot rather than a fiber issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.34592.1.5.1.1.2.17.2.1.1
snmpwalk -v2c -c public <target> CDATA-GPON-MIB::gponOltPortDdmTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.34592.1.5.1.1.2.17.2.1.1.1
snmpget -v2c -c public <target> CDATA-GPON-MIB::gponOltPortDdmTemperature.1

Start monitoring C-Data Technology EPON/GPON OLT access equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDATA-GPON-MIB::gponOltPortDdmTemperature OID value, configure state conditions and alerts, and monitor any C-Data Technology EPON/GPON OLT access equipment from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.34592vendorCDATA-COMMON-SMI
1.3.6.1.4.1.34592.1ipProductCDATA-COMMON-SMI
1.3.6.1.4.1.34592.1.5gponCDATA-COMMON-SMI
Numeric OIDNameModule
1.3.6.1.4.1.34592.1.5.1gponMIBCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1gponObjectsCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2gponControlObjectsCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.17gponOltObjectsCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.17.2gponOltPortDdmInfoTableCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.17.2.1gponOltPortDdmInfoEntryCDATA-GPON-MIB
1.3.6.1.4.1.34592.1.5.1.1.2.17.2.1.1gponOltPortDdmTemperatureCDATA-GPON-MIB