CCPOWER-MIB :: reconnect2LoadShedSaturdayOn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCCPOWER-MIBreconnect2LoadShedSaturdayOn

reconnect2LoadShedSaturdayOn

Module: CCPOWER-MIB

OID (symbolic): CCPOWER-MIB::reconnect2LoadShedSaturdayOn

OID (numeric): 1.3.6.1.4.1.18642.1.1.1.47

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: Time on Saturday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.

What is reconnect2LoadShedSaturdayOn?

This is the scheduled clock time (HH:MM) on Saturday at which load bank 2, previously shed earlier that day by disconnect2LoadShedSaturdayOff, is scheduled to reconnect, per the description. Pairing this reconnect time with disconnect2LoadShedSaturdayOff defines bank 2's full shed window for Saturday, which as the middle-priority tier is typically shorter than bank 1's window but longer than bank 3's. A value of '08:00' paired with an Off time of '21:00' on the same Saturday defines that day's full overnight shed window for bank 2; if the On time were set earlier than the Off time, that day's schedule would effectively do nothing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18642.1.1.1.47
snmpwalk -v2c -c public <target> CCPOWER-MIB::reconnect2LoadShedSaturdayOn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18642.1.1.1.47.1
snmpget -v2c -c public <target> CCPOWER-MIB::reconnect2LoadShedSaturdayOn.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18642.1.1.1.47.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> reconnect2LoadShedSaturdayOn.1

Start monitoring DC rectifier/power-plant equipment (enterprise OID 18642) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CCPOWER-MIB::reconnect2LoadShedSaturdayOn OID value, configure state conditions and alerts, and monitor any DC rectifier/power-plant equipment (enterprise OID 18642) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18642ccpowerCCPOWER-MIB
1.3.6.1.4.1.18642.1dcSystemCCPOWER-MIB
1.3.6.1.4.1.18642.1.1readWriteObjectsCCPOWER-MIB
1.3.6.1.4.1.18642.1.1.1settingsCCPOWER-MIB
1.3.6.1.4.1.18642.1.1.1.47reconnect2LoadShedSaturdayOnCCPOWER-MIB