CASCADE-MIB :: svcAtmConfigQSaalNumEndPduTx

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCASCADE-MIBsvcAtmConfigQSaalNumEndPduTx

svcAtmConfigQSaalNumEndPduTx

Module: CASCADE-MIB

OID (symbolic): CASCADE-MIB::svcAtmConfigQSaalNumEndPduTx

OID (numeric): 1.3.6.1.4.1.277.5.2.2.1.67

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: The number of end PDU's transmitted on this port.

What is svcAtmConfigQSaalNumEndPduTx?

This counter tracks the number of END PDUs transmitted on this port, per the description, where END is the SSCOP message that gracefully terminates the signaling data link connection (as opposed to a single SVC being released). Because tearing down the whole signaling link takes every SVC riding on it down with it, a rise in this counter is far more consequential than a rise in svcAtmConfigQ93bNumReleasePdu and should prompt checking why the signaling channel itself is being closed rather than just individual calls. This is typically only expected during planned maintenance or card resets.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.5.2.2.1.67
snmpwalk -v2c -c public <target> CASCADE-MIB::svcAtmConfigQSaalNumEndPduTx

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.277.5.2.2.1.67.1
snmpget -v2c -c public <target> CASCADE-MIB::svcAtmConfigQSaalNumEndPduTx.1

Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::svcAtmConfigQSaalNumEndPduTx OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.277cascadeCASCADE-MIB
1.3.6.1.4.1.277.5cascsvcCASCADE-MIB
1.3.6.1.4.1.277.5.2svcmgtCASCADE-MIB
1.3.6.1.4.1.277.5.2.2svcAtmConfigTableCASCADE-MIB
1.3.6.1.4.1.277.5.2.2.1svcAtmConfigEntryCASCADE-MIB
1.3.6.1.4.1.277.5.2.2.1.67svcAtmConfigQSaalNumEndPduTxCASCADE-MIB