CASCADE-MIB :: pportds1FDLControl

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCASCADE-MIBpportds1FDLControl

pportds1FDLControl

Module: CASCADE-MIB

OID (symbolic): CASCADE-MIB::pportds1FDLControl

OID (numeric): 1.3.6.1.4.1.277.1.4.2.1.112

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Enables or Disables FDL Function for DS1 ESF pport

What is pportds1FDLControl?

This enables or disables the Facility Data Link (FDL) function on this DS1 ESF port. The FDL is the ESF framing overhead channel used to carry performance reports and messages between the two ends of the circuit, so disabling it on this specific port cuts off features like automated performance monitoring exchange (pportds1FDLPrmXmit) and path ID messaging with the far end. A carrier requiring FDL-based performance report exchange on a leased DS1 circuit would need pportds1FDLControl enabled on this port for that monitoring data to actually be sent and received.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.4.2.1.112
snmpwalk -v2c -c public <target> CASCADE-MIB::pportds1FDLControl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.4.2.1.112.1
snmpget -v2c -c public <target> CASCADE-MIB::pportds1FDLControl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.277.1.4.2.1.112.1 i <value>

Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::pportds1FDLControl OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.277cascadeCASCADE-MIB
1.3.6.1.4.1.277.1cascfrCASCADE-MIB
1.3.6.1.4.1.277.1.4pportCASCADE-MIB
1.3.6.1.4.1.277.1.4.2pportTableCASCADE-MIB
1.3.6.1.4.1.277.1.4.2.1pportEntryCASCADE-MIB
1.3.6.1.4.1.277.1.4.2.1.112pportds1FDLControlCASCADE-MIB