CASCADE-MIB :: pportOutDiscards

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCASCADE-MIBpportOutDiscards

pportOutDiscards

Module: CASCADE-MIB

OID (symbolic): CASCADE-MIB::pportOutDiscards

OID (numeric): 1.3.6.1.4.1.277.1.4.2.1.22

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: The total number of outbound frames discarded due to severe congestion.

What is pportOutDiscards?

This counts outbound frames on this physical port that were discarded specifically because of severe congestion, as opposed to errors. Because the description ties this explicitly to severe congestion, a nonzero and climbing value here means this port's egress queue is being overwhelmed and traffic shaping or the port's provisioned CIR/PIR should be reviewed for this specific circuit. A PVC-heavy port that starts accumulating pportOutDiscards right after a new high-bandwidth customer is added would suggest that circuit is oversubscribing this port's available egress bandwidth.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.4.2.1.22
snmpwalk -v2c -c public <target> CASCADE-MIB::pportOutDiscards

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.4.2.1.22.1
snmpget -v2c -c public <target> CASCADE-MIB::pportOutDiscards.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> pportOutDiscards.1

Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::pportOutDiscards OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.277cascadeCASCADE-MIB
1.3.6.1.4.1.277.1cascfrCASCADE-MIB
1.3.6.1.4.1.277.1.4pportCASCADE-MIB
1.3.6.1.4.1.277.1.4.2pportTableCASCADE-MIB
1.3.6.1.4.1.277.1.4.2.1pportEntryCASCADE-MIB