CASCADE-MIB :: nodePsADiagCode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCASCADE-MIBnodePsADiagCode

nodePsADiagCode

Module: CASCADE-MIB

OID (symbolic): CASCADE-MIB::nodePsADiagCode

OID (numeric): 1.3.6.1.4.1.277.1.3.58

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The failure code of the power supply A. A non-zero value indicates one or more failures. Refer to the hardware manual for a description of the failure code.

What is nodePsADiagCode?

This reports a numeric failure code for power supply A, with any non-zero value indicating one or more specific failures whose meaning is documented in the hardware manual, providing the detail behind the general status reported in nodePsAStatus. A technician looks up the specific non-zero value in nodePsADiagCode against the hardware manual's fault table to know exactly what's wrong with supply A before ordering a replacement part.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.3.58
snmpwalk -v2c -c public <target> CASCADE-MIB::nodePsADiagCode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.3.58.1
snmpget -v2c -c public <target> CASCADE-MIB::nodePsADiagCode.1

Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::nodePsADiagCode OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.277cascadeCASCADE-MIB
1.3.6.1.4.1.277.1cascfrCASCADE-MIB
1.3.6.1.4.1.277.1.3nodeCASCADE-MIB
1.3.6.1.4.1.277.1.3.58nodePsADiagCodeCASCADE-MIB