All MIBs › CASCADE-MIB › nodeOamAlarmDisabled
nodeOamAlarmDisabled
Module: CASCADE-MIB
OID (symbolic): CASCADE-MIB::nodeOamAlarmDisabled
OID (numeric): 1.3.6.1.4.1.277.1.3.76
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: If disabled then don't generate oam alarms for circuits that are down on this switch.
What is nodeOamAlarmDisabled?
Setting this to disabled(2) stops the switch from generating OAM alarms for circuits that are down, useful for suppressing alarm noise on ports or circuits known to be intentionally out of service. An admin sets nodeOamAlarmDisabled to disabled(2) during planned circuit decommissioning to avoid a flood of down-circuit alarms cluttering the NMS during the transition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.3.76 snmpwalk -v2c -c public <target> CASCADE-MIB::nodeOamAlarmDisabled
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.3.76.1 snmpget -v2c -c public <target> CASCADE-MIB::nodeOamAlarmDisabled.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.277.1.3.76.1 i <value>
Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::nodeOamAlarmDisabled OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.277 | cascade | CASCADE-MIB |
| 1.3.6.1.4.1.277.1 | cascfr | CASCADE-MIB |
| 1.3.6.1.4.1.277.1.3 | node | CASCADE-MIB |
| 1.3.6.1.4.1.277.1.3.76 | nodeOamAlarmDisabled | CASCADE-MIB |