CASCADE-MIB :: nodeDiagPowerExtensive

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCASCADE-MIBnodeDiagPowerExtensive

nodeDiagPowerExtensive

Module: CASCADE-MIB

OID (symbolic): CASCADE-MIB::nodeDiagPowerExtensive

OID (numeric): 1.3.6.1.4.1.277.1.3.53

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Should power on diagnostics do slower, extensive testing, or fast testing?

What is nodeDiagPowerExtensive?

This configures whether the switch's power-on self-test runs the slower, more thorough diagnostic suite or the faster, lighter one on its next boot. An admin sets nodeDiagPowerExtensive to extensive-tests(1) before a suspected-hardware-fault reboot to get more thorough self-test coverage, accepting a longer boot time in exchange for better fault detection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.3.53
snmpwalk -v2c -c public <target> CASCADE-MIB::nodeDiagPowerExtensive

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.3.53.1
snmpget -v2c -c public <target> CASCADE-MIB::nodeDiagPowerExtensive.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.277.1.3.53.1 i <value>

Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::nodeDiagPowerExtensive OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.277cascadeCASCADE-MIB
1.3.6.1.4.1.277.1cascfrCASCADE-MIB
1.3.6.1.4.1.277.1.3nodeCASCADE-MIB
1.3.6.1.4.1.277.1.3.53nodeDiagPowerExtensiveCASCADE-MIB