CASCADE-MIB :: lportSVCRetryTimer

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCASCADE-MIBlportSVCRetryTimer

lportSVCRetryTimer

Module: CASCADE-MIB

OID (symbolic): CASCADE-MIB::lportSVCRetryTimer

OID (numeric): 1.3.6.1.4.1.277.1.5.1.1.204

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The duration in seconds (1..255) the network is allowed to re-establish a SVC after network failure before clearing the SVC. A value of (0) indicates continuous retries by the network until the user clears the SVC.

What is lportSVCRetryTimer?

This read-write value sets how long, in seconds, 1 to 255, the network will keep attempting to re-establish a Switched Virtual Circuit after a network-side failure before giving up and clearing the SVC entirely, with a special value of 0 meaning the network retries continuously until the user side explicitly clears the call. An admin tunes this to control how persistent the network is about recovering a dropped SVC versus quickly freeing up the resources for other calls. For example, setting lportSVCRetryTimer to 30 means the network will keep trying to restore a failed SVC for half a minute before giving up and tearing it down, whereas 0 would have it retry indefinitely until the user actively clears it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.5.1.1.204
snmpwalk -v2c -c public <target> CASCADE-MIB::lportSVCRetryTimer

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.5.1.1.204.1
snmpget -v2c -c public <target> CASCADE-MIB::lportSVCRetryTimer.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.277.1.5.1.1.204.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lportSVCRetryTimer.1

Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::lportSVCRetryTimer OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.277cascadeCASCADE-MIB
1.3.6.1.4.1.277.1cascfrCASCADE-MIB
1.3.6.1.4.1.277.1.5lportCASCADE-MIB
1.3.6.1.4.1.277.1.5.1lportTableCASCADE-MIB
1.3.6.1.4.1.277.1.5.1.1lportEntryCASCADE-MIB
1.3.6.1.4.1.277.1.5.1.1.204lportSVCRetryTimerCASCADE-MIB