CASCADE-MIB :: lportDataRate

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCASCADE-MIBlportDataRate

lportDataRate

Module: CASCADE-MIB

OID (symbolic): CASCADE-MIB::lportDataRate

OID (numeric): 1.3.6.1.4.1.277.1.5.1.1.34

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: An estimate of the logical port's data rate in bits per second.

What is lportDataRate?

This holds the configured or estimated data rate, in bits per second, that the logical port is provisioned to carry, which downstream calculations like lportTrkUtil and lportTrkOverhead use as their baseline 100% bandwidth figure. An admin sets this to match the actual contracted or physical line rate so utilization percentages reported elsewhere are meaningful. For example, if a T1-based Frame Relay port is provisioned for 1.536 Mbps, setting lportDataRate to that value ensures lportTrkUtil correctly reflects real-world percentage utilization rather than being skewed by a wrong baseline.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.5.1.1.34
snmpwalk -v2c -c public <target> CASCADE-MIB::lportDataRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.5.1.1.34.1
snmpget -v2c -c public <target> CASCADE-MIB::lportDataRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.277.1.5.1.1.34.1 i <value>

Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::lportDataRate OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.277cascadeCASCADE-MIB
1.3.6.1.4.1.277.1cascfrCASCADE-MIB
1.3.6.1.4.1.277.1.5lportCASCADE-MIB
1.3.6.1.4.1.277.1.5.1lportTableCASCADE-MIB
1.3.6.1.4.1.277.1.5.1.1lportEntryCASCADE-MIB
1.3.6.1.4.1.277.1.5.1.1.34lportDataRateCASCADE-MIB