All MIBs › CASCADE-MIB › cardBTUsNoResource
cardBTUsNoResource
Module: CASCADE-MIB
OID (symbolic): CASCADE-MIB::cardBTUsNoResource
OID (numeric): 1.3.6.1.4.1.277.1.7.2.1.194
Node type: OBJECT-TYPE
Type: Counter
Access: read-write
Description: The number of BTUs received by this card over the Cell Bus which were discarded due to no free BTUs available to replace it.
What is cardBTUsNoResource?
This counter tracks how many BTUs (the switch's internal cell/frame transfer units carried across the backplane Cell Bus) arriving at this card were dropped because the card had no free BTU buffer to hand back in exchange, per the description. A rising count here means this specific card's BTU pool is being exhausted faster than the backplane can replenish it, which on a Cascade switch shows up as intermittent cell/frame loss on that card's ports even though the physical link itself looks fine. For example, seeing this counter jump from 0 to several thousand over a busy hour on a heavily trunked ATM card would point to backplane buffer starvation on that specific card rather than a wiring or carrier problem.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.277.1.7.2.1.194 snmpwalk -v2c -c public <target> CASCADE-MIB::cardBTUsNoResource
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.277.1.7.2.1.194.1 snmpget -v2c -c public <target> CASCADE-MIB::cardBTUsNoResource.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.277.1.7.2.1.194.1 i <value>
Start monitoring Cascade Communications ATM/Frame Relay switches (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CASCADE-MIB::cardBTUsNoResource OID value, configure state conditions and alerts, and monitor any Cascade Communications ATM/Frame Relay switches (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.277 | cascade | CASCADE-MIB |
| 1.3.6.1.4.1.277.1 | cascfr | CASCADE-MIB |
| 1.3.6.1.4.1.277.1.7 | card | CASCADE-MIB |
| 1.3.6.1.4.1.277.1.7.2 | cardTable | CASCADE-MIB |
| 1.3.6.1.4.1.277.1.7.2.1 | cardEntry | CASCADE-MIB |
| 1.3.6.1.4.1.277.1.7.2.1.194 | cardBTUsNoResource | CASCADE-MIB |