CADANT-REMOTE-QUERY-MIB :: cadCmRemoteQuerySigQMicroreflections

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CADANT-REMOTE-QUERY-MIB › cadCmRemoteQuerySigQMicroreflections

cadCmRemoteQuerySigQMicroreflections

Module: CADANT-REMOTE-QUERY-MIB

OID (symbolic): CADANT-REMOTE-QUERY-MIB::cadCmRemoteQuerySigQMicroreflections

OID (numeric): 1.3.6.1.4.1.4998.1.1.55.1.2.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Total microreflections including in-channel response as perceived on the CM downstream, measured in dBc below the signal level.

This object is not assumed to return an absolutely accurate value, but is meant to give a rough indication of microreflections received on this interface. It is up to the implementor to provide information as accurate as possible.

What is cadCmRemoteQuerySigQMicroreflections?

Reports the total level of microreflections perceived on the cable modem's downstream channel, measured in dBc below the main signal level. High microreflection values indicate impedance mismatches or signal echoes in the coaxial plant that can degrade channel quality.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.55.1.2.1.6
snmpwalk -v2c -c public <target> CADANT-REMOTE-QUERY-MIB::cadCmRemoteQuerySigQMicroreflections

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.55.1.2.1.6.1
snmpget -v2c -c public <target> CADANT-REMOTE-QUERY-MIB::cadCmRemoteQuerySigQMicroreflections.1

Start monitoring ARRIS/Cadant CMTS devices and cable modems with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CADANT-REMOTE-QUERY-MIB::cadCmRemoteQuerySigQMicroreflections OID value, configure state conditions and alerts, and monitor any ARRIS/Cadant CMTS devices and cable modems from a single console.

How to Use in IPNetwork Monitor

Select an ARRIS/Cadant CMTS device or cable modem as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cadCmRemoteQuerySigQMicroreflections into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the total microreflections including in-channel response as perceived on the CM downstream, measured in dBc below the signal level. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4998cadantCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1cadObjectsCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1cadCableCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1.55cadCmRemoteQueryCADANT-PRODUCTS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4998.1.1.55.1cadCmRemoteQueryMibCADANT-REMOTE-QUERY-MIB
1.3.6.1.4.1.4998.1.1.55.1.2cadCmRemoteQueryStatusTableCADANT-REMOTE-QUERY-MIB
1.3.6.1.4.1.4998.1.1.55.1.2.1cadCmRemoteQueryStatusEntryCADANT-REMOTE-QUERY-MIB