CABH-CDP-MIB :: cabhCdpTimeOffsetSelection

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCABH-CDP-MIBcabhCdpTimeOffsetSelection

cabhCdpTimeOffsetSelection

Module: CABH-CDP-MIB

OID (symbolic): CABH-CDP-MIB::cabhCdpTimeOffsetSelection

OID (numeric): 1.3.6.1.4.1.4491.2.4.4.1.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object selects the source to be used by the PS in determining the time offset to the time of day acquired from the time server. It is intended to be used in cases where the time zone information provisioned by the ToD server or DHCP Server (in DHCP Option 2) is different from the time zone where the provisioned device is physically located.

Setting this object to useDhcpOption2(1) configures the PS to use the value of DHCP Option 2 from the DHCP ACK message for time of day offset. Setting this object to useSnmpSetOffset(2) configures the PS to use the value of cabhCdpServerSnmpSetTimeOffset for time of day offset, and to ignore DHCP Option 2. When the value of this object is changed the PS MUST immediately begin using the time offset specified by the value of this object, regardless of which time offset the PS was using before the update occurred.

What is cabhCdpTimeOffsetSelection?

Selects which source the PS uses to determine its UTC time offset — for example, the Time-of-Day server, DHCP option, or an SNMP-provisioned value. This is particularly useful when serving devices across multiple time zones.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.4.4.1.1.7
snmpwalk -v2c -c public <target> CABH-CDP-MIB::cabhCdpTimeOffsetSelection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.4.4.1.1.7.1
snmpget -v2c -c public <target> CABH-CDP-MIB::cabhCdpTimeOffsetSelection.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4491.2.4.4.1.1.7.1 i <value>

Start monitoring CableHome-compliant residential gateways (cable modem/router) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CABH-CDP-MIB::cabhCdpTimeOffsetSelection OID value, configure state conditions and alerts, and monitor any CableHome-compliant residential gateways (cable modem/router) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.4clabProjCableHomeCLAB-DEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.4.4cabhCdpMibCABH-CDP-MIB
1.3.6.1.4.1.4491.2.4.4.1cabhCdpObjectsCABH-CDP-MIB
1.3.6.1.4.1.4491.2.4.4.1.1cabhCdpBaseCABH-CDP-MIB
1.3.6.1.4.1.4491.2.4.4.1.1.7cabhCdpTimeOffsetSelectionCABH-CDP-MIB