BTI-7000-MIB :: stmnCrntPMOPTMinValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBstmnCrntPMOPTMinValue

stmnCrntPMOPTMinValue

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::stmnCrntPMOPTMinValue

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.14.1.132

Node type: OBJECT-TYPE

Type: FixedX10

Access: read-only

Description: The minimum optical power transmitted at the output of the transceiver.

What is stmnCrntPMOPTMinValue?

Reports the minimum optical power level transmitted at the transceiver output during the current monitoring interval. Low minimum transmit power may indicate laser degradation or a hardware fault in the optical interface.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.14.1.132
snmpwalk -v2c -c public <target> BTI-7000-MIB::stmnCrntPMOPTMinValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.14.1.132.1
snmpget -v2c -c public <target> BTI-7000-MIB::stmnCrntPMOPTMinValue.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::stmnCrntPMOPTMinValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.14stmnCrntPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.14.1stmnCrntPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.14.1.132stmnCrntPMOPTMinValueBTI-7000-MIB