BTI-7000-MIB :: stmnCrntPMOPRAvgValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBstmnCrntPMOPRAvgValue

stmnCrntPMOPRAvgValue

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::stmnCrntPMOPRAvgValue

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.14.1.128

Node type: OBJECT-TYPE

Type: FixedX10

Access: read-only

Description: The average optical power received on the input of the transceiver.

What is stmnCrntPMOPRAvgValue?

Reports the average optical power received at the transceiver input over the current performance monitoring period. This value provides a smoothed view of received signal strength and helps detect gradual power drift.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.14.1.128
snmpwalk -v2c -c public <target> BTI-7000-MIB::stmnCrntPMOPRAvgValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.14.1.128.1
snmpget -v2c -c public <target> BTI-7000-MIB::stmnCrntPMOPRAvgValue.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::stmnCrntPMOPRAvgValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.14stmnCrntPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.14.1stmnCrntPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.14.1.128stmnCrntPMOPRAvgValueBTI-7000-MIB