ocnOpticalPwrTransmittedMinTh

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::ocnOpticalPwrTransmittedMinTh

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.4.5.1.7

Node type: OBJECT-TYPE

Type: FixedX10

Access: read-only

Description: This is the optical power transmitted minimum threshold.

What is ocnOpticalPwrTransmittedMinTh?

Reports the minimum threshold for optical power transmitted by an OC-N port transceiver. Signal conditions falling below this level can indicate a fault or degraded transmit path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.4.5.1.7
snmpwalk -v2c -c public <target> BTI-7000-MIB::ocnOpticalPwrTransmittedMinTh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.4.5.1.7.1
snmpget -v2c -c public <target> BTI-7000-MIB::ocnOpticalPwrTransmittedMinTh.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::ocnOpticalPwrTransmittedMinTh OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4facilitiesBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4.5ocnTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4.5.1ocnEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4.5.1.7ocnOpticalPwrTransmittedMinThBTI-7000-MIB