Access: read-only
Description: The maximum optical power transmitted at the output of the transceiver.
What is ocnHistPMOPTMaxValue?
Reports the highest optical transmit power level recorded at the transceiver output during the historical monitoring period. This peak value helps engineers assess whether the signal ever exceeded safe or specified transmission limits.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.9.1.129 snmpwalk -v2c -c public <target> BTI-7000-MIB::ocnHistPMOPTMaxValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.9.1.129.1 snmpget -v2c -c public <target> BTI-7000-MIB::ocnHistPMOPTMaxValue.1
Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::ocnHistPMOPTMaxValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18070 | btiSystems | BTI-MIB |
| 1.3.6.1.4.1.18070.2 | btiProducts | BTI-MIB |
| 1.3.6.1.4.1.18070.2.2 | bti7000 | BTI-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18070.2.2.1 | objects | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6 | performance | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.9 | ocnHistPMTable | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.9.1 | ocnHistPMEntry | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.9.1.129 | ocnHistPMOPTMaxValue | BTI-7000-MIB |