BTI-7000-MIB :: ocnHistPMOPRMaxValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBocnHistPMOPRMaxValue

ocnHistPMOPRMaxValue

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::ocnHistPMOPRMaxValue

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.9.1.117

Node type: OBJECT-TYPE

Type: FixedX10

Access: read-only

Description: The maximum optical power received on the input of the transceiver.

What is ocnHistPMOPRMaxValue?

Reports the maximum optical power level received at the transceiver input during a historical interval. Unusually high receive power may indicate amplifier gain issues or improper attenuation on the optical path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.9.1.117
snmpwalk -v2c -c public <target> BTI-7000-MIB::ocnHistPMOPRMaxValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.9.1.117.1
snmpget -v2c -c public <target> BTI-7000-MIB::ocnHistPMOPRMaxValue.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::ocnHistPMOPRMaxValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.9ocnHistPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.9.1ocnHistPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.9.1.117ocnHistPMOPRMaxValueBTI-7000-MIB