BTI-7000-MIB :: oaCrntPMOBRValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBoaCrntPMOBRValue

oaCrntPMOBRValue

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::oaCrntPMOBRValue

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.1.1.45

Node type: OBJECT-TYPE

Type: FixedX10

Access: read-only

Description: The back reflected optical power measured at the output of the second stage of the optical amplifier.

What is oaCrntPMOBRValue?

Measures the optical power reflected back from the output of the second stage of the amplifier, known as optical back reflection (OBR). Elevated back reflection levels can indicate fiber faults or connector problems and may degrade amplifier performance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.1.1.45
snmpwalk -v2c -c public <target> BTI-7000-MIB::oaCrntPMOBRValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.1.1.45.1
snmpget -v2c -c public <target> BTI-7000-MIB::oaCrntPMOBRValue.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::oaCrntPMOBRValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.1oaCrntPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.1.1oaCrntPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.1.1.45oaCrntPMOBRValueBTI-7000-MIB