BTI-7000-MIB :: oaCrntPMCaseTempValidity

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBoaCrntPMCaseTempValidity

oaCrntPMCaseTempValidity

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::oaCrntPMCaseTempValidity

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.1.1.8

Node type: OBJECT-TYPE

Type: PMValidity

Access: read-only

Description: Indicates the validity of the provided case temperature value.

What is oaCrntPMCaseTempValidity?

Indicates whether the current optical amplifier case temperature reading is valid and reliable. An invalid validity flag may signal that the measurement could not be taken or is out of range.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.1.1.8
snmpwalk -v2c -c public <target> BTI-7000-MIB::oaCrntPMCaseTempValidity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.1.1.8.1
snmpget -v2c -c public <target> BTI-7000-MIB::oaCrntPMCaseTempValidity.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::oaCrntPMCaseTempValidity OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.1oaCrntPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.1.1oaCrntPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.1.1.8oaCrntPMCaseTempValidityBTI-7000-MIB