BTI-7000-MIB :: geSpeed

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBgeSpeed

geSpeed

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::geSpeed

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.4.9.1.26

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The speed of the Gigabit Ethernet facility link.

What is geSpeed?

This OID reports the current link speed of a Gigabit Ethernet facility interface, such as 100 Mbps or 1 Gbps. It is a read-only value reflecting the negotiated or detected speed of the connection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.4.9.1.26
snmpwalk -v2c -c public <target> BTI-7000-MIB::geSpeed

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.4.9.1.26.1
snmpget -v2c -c public <target> BTI-7000-MIB::geSpeed.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::geSpeed OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

How to Use in IPNetwork Monitor

Select a BTI Systems optical transport device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type geSpeed into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The speed of the Gigabit Ethernet facility link. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline (in Mbps), since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4facilitiesBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4.9geTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4.9.1geEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.4.9.1.26geSpeedBTI-7000-MIB