BTI-7000-MIB :: geHistPMSIZE512To1023Initialize

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBgeHistPMSIZE512To1023Initialize

geHistPMSIZE512To1023Initialize

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::geHistPMSIZE512To1023Initialize

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.21.1.79

Node type: OBJECT-TYPE

Type: InitializeCmd

Access: read-write

Description: Used to initialize the value of the geHistPMSIZE512To1023Value object to 0.

What is geHistPMSIZE512To1023Initialize?

A writable control object used to reset the 512-to-1023-byte frame counter back to zero. Writing to this object clears the accumulated count so a fresh measurement period can begin.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.21.1.79
snmpwalk -v2c -c public <target> BTI-7000-MIB::geHistPMSIZE512To1023Initialize

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.21.1.79.1
snmpget -v2c -c public <target> BTI-7000-MIB::geHistPMSIZE512To1023Initialize.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18070.2.2.1.6.21.1.79.1 s <value>

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::geHistPMSIZE512To1023Initialize OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.21geHistPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.21.1geHistPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.21.1.79geHistPMSIZE512To1023InitializeBTI-7000-MIB