BTI-7000-MIB :: geHistPMOPTMaxInitialize

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBgeHistPMOPTMaxInitialize

geHistPMOPTMaxInitialize

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::geHistPMOPTMaxInitialize

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.21.1.140

Node type: OBJECT-TYPE

Type: InitializeCmd

Access: read-write

Description: Used to initialize the value of the geHistPMOPTMaxValue object to 0.

What is geHistPMOPTMaxInitialize?

A write-only control used to reset the historical maximum optical power transmitted (OPT) measurement back to zero. This allows operators to clear the peak value and restart the tracking of the maximum transmit power.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.21.1.140
snmpwalk -v2c -c public <target> BTI-7000-MIB::geHistPMOPTMaxInitialize

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.21.1.140.1
snmpget -v2c -c public <target> BTI-7000-MIB::geHistPMOPTMaxInitialize.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18070.2.2.1.6.21.1.140.1 s <value>

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::geHistPMOPTMaxInitialize OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.21geHistPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.21.1geHistPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.21.1.140geHistPMOPTMaxInitializeBTI-7000-MIB