Description: The supply voltage measured on the FC facility port.
What is fcHistPMSupplyVoltageValue?
Reports the historical supply voltage level measured on the FC facility port. This value is used to monitor the electrical health of the optical transceiver over time.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.24.1.15 snmpwalk -v2c -c public <target> BTI-7000-MIB::fcHistPMSupplyVoltageValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.24.1.15.1 snmpget -v2c -c public <target> BTI-7000-MIB::fcHistPMSupplyVoltageValue.1
Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::fcHistPMSupplyVoltageValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18070 | btiSystems | BTI-MIB |
| 1.3.6.1.4.1.18070.2 | btiProducts | BTI-MIB |
| 1.3.6.1.4.1.18070.2.2 | bti7000 | BTI-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18070.2.2.1 | objects | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6 | performance | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.24 | fcHistPMTable | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.24.1 | fcHistPMEntry | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.24.1.15 | fcHistPMSupplyVoltageValue | BTI-7000-MIB |