All MIBs › BTI-7000-MIB › fcCrntPMOPTMaxValidity
fcCrntPMOPTMaxValidity
Module: BTI-7000-MIB
OID (symbolic): BTI-7000-MIB::fcCrntPMOPTMaxValidity
OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.23.1.54
Node type: OBJECT-TYPE
Type: PMValidity
Access: read-only
Description: Indicates the validity of the provided maximum optical power transmitted value.
What is fcCrntPMOPTMaxValidity?
Indicates whether the current-interval maximum optical transmit power reading is valid and can be used for performance analysis. An invalid flag signals that the peak value may be unreliable.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.23.1.54 snmpwalk -v2c -c public <target> BTI-7000-MIB::fcCrntPMOPTMaxValidity
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.23.1.54.1 snmpget -v2c -c public <target> BTI-7000-MIB::fcCrntPMOPTMaxValidity.1
Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::fcCrntPMOPTMaxValidity OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18070 | btiSystems | BTI-MIB |
| 1.3.6.1.4.1.18070.2 | btiProducts | BTI-MIB |
| 1.3.6.1.4.1.18070.2.2 | bti7000 | BTI-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18070.2.2.1 | objects | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6 | performance | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.23 | fcCrntPMTable | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.23.1 | fcCrntPMEntry | BTI-7000-MIB |
| 1.3.6.1.4.1.18070.2.2.1.6.23.1.54 | fcCrntPMOPTMaxValidity | BTI-7000-MIB |