BTI-7000-MIB :: fcCrntPMLBCValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBfcCrntPMLBCValue

fcCrntPMLBCValue

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::fcCrntPMLBCValue

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.23.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The laser bias current measured on the FC facility port.

What is fcCrntPMLBCValue?

Reports the laser bias current currently flowing through the laser diode on the Fibre Channel facility port. Monitoring laser bias current helps detect aging or degradation of the optical transmitter before it causes failures.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.23.1.17
snmpwalk -v2c -c public <target> BTI-7000-MIB::fcCrntPMLBCValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.23.1.17.1
snmpget -v2c -c public <target> BTI-7000-MIB::fcCrntPMLBCValue.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::fcCrntPMLBCValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.23fcCrntPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.23.1fcCrntPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.23.1.17fcCrntPMLBCValueBTI-7000-MIB